Flange valve installation

Classification:

Release Time:2019-05-30

Flange valve is connected to the flange of the valve, the valve body with flange, and pipe flange connection, common flange gate valve, flange globe valve and so on, most of the valves can be used flange connection. Flange valve installation instructions: 1. The verticality between the flange surface on the pipe and the center line of the pipe and the error of the flange bolt hole should be within the allowable range. The valve and the center line of the pipe should be consistent before installation. 2. Flange faces of valves and piping shall be free of damage, scratches, dirt, etc. Especially when the metal gasket is used, the groove of the flange should be consistent with the gasket to ensure that it is in good sealing condition. 3. Tightness of flange

Flange valve is connected to the flange of the valve, the valve body with flange, and pipe flange connection, common flange gate valve, flange globe valve and so on, most of the valves can be used flange connection.

Flange valve installation instructions:

1. The verticality between the flange surface on the pipe and the center line of the pipe and the error of the flange bolt hole should be within the allowable range. The valve and the center line of the pipe should be consistent before installation.

2. Flange faces of valves and piping shall be free of damage, scratches, dirt, etc. Especially when the metal gasket is used, the groove of the flange should be consistent with the gasket to ensure that it is in good sealing condition.

3, flange fastening to avoid uneven force, should be in accordance with the symmetrical, cross the direction of the sequence of tightening.

4. When tightening bolts, use a wrench that matches the nut. When using oil pressure and air tools for tightening, be careful not to exceed the specified torque.

5. When connecting two flanges, first make the flange sealing surface and gasket evenly compressed, thus ensuring that the flange is connected with the same bolt stress.

6. After the flange is installed, make sure that all bolts and nuts are tightened evenly.

7. Fastening bolts and nuts, in order to prevent loosening caused by vibration, use washers. In order to avoid the adhesion between the threads at high temperature, the thread should be coated with anti-sticking agent during installation.

8. For high temperature valves, after the temperature rises, the flange connecting bolts, valve cover fastening bolts, pressure seals and packing gland bolts must be tightened again.

9, low temperature when the valve is installed in the state of atmospheric temperature, due to the formation of temperature difference, flanges, gaskets, bolts and nuts, such as shrinkage, and because these parts of the material is not the same, their linear expansion coefficient is also different, the formation of a very easy to leak the environmental conditions. From this objective situation, when tightening the bolts at atmospheric temperature, the torque that takes into account the shrinkage factors of the parts at low temperatures must be used.

WeChat Public Number
Mobile phone official website
WeChat Public Number

Contact Information

+86 27-8970 8339

Tel: +86 27-8970 8619

WhatsApp: +86 181 7126 2929

E-mail: whylgd@vip.163.com

Address: No.5, Zhengjie, Shuangliu Street, Xinzhou District, Wuhan City, Hubei Province