Causes and solutions of lax valve closure

Classification:

Release Time:2018-10-10

During the use of the valve, there are often some perplexing problems, such as the valve is not closed tightly or tightly. If the valve is not closed tightly, first confirm whether the valve is closed in place. If there is still leakage and cannot be sealed after it has been closed in place, then check the sealing surface. Some valve sealing pairs are detachable, then take them out for grinding and testing again, if it is still not strictly closed, it must be returned to the factory for maintenance or replacement of the valve, so as not to affect the normal use of the valve and the occurrence of working conditions and other problems. If the valve is not closed tightly, first find out where the problem occurs, however

During the use of the valve, there are often some perplexing problems, such as the valve is not closed tightly or tightly. If the valve is not closed tightly, first confirm whether the valve is closed in place. If there is still leakage and cannot be sealed after it has been closed in place, then check the sealing surface. Some valve sealing pairs are detachable, then take them out for grinding and testing again, if it is still not strictly closed, it must be returned to the factory for maintenance or replacement of the valve, so as not to affect the normal use of the valve and the occurrence of working conditions and other problems.

If the valve is not closed tightly, first of all, we should find out where the problem occurs, and then solve the problem according to the corresponding method. General valve is not strict for the following reasons:

(1) impurities stuck in the sealing surface, debris deposited at the bottom of the valve or pad between the valve and the valve seat;

(2) The thread of the valve stem is rusty and the valve cannot rotate;

(3) The valve sealing surface is destroyed, resulting in leakage of the medium;

(4) stem and valve disc connection is not good, so that the valve disc and valve seat deflection can not be close contact.

valve closed lax processing method:

1. there are impurities stuck valve sealing surface

Valve sometimes suddenly closed lax, may be between the valve sealing surface impurities stuck, at this time should not be forced to close, the valve should be slightly larger, and then try to close, the general can be excluded, otherwise should be checked, should keep the quality of the medium clean.

2. stem thread rust

For valves that are usually in the open state, when they are accidentally closed, because the stem thread has rusted, it will also happen. In this case, the valve can be repeatedly switched several times, while hitting the bottom of the valve body with a small hammer, which can close the valve tightly, without grinding and repairing the valve.

3. valve sealing surface is damaged

For the case that the switch is still not closed after trying many times, that is, the sealing surface is damaged and should be reported for repair. Or corrosion, particles in the medium scratch and other damage to the sealing surface, should also be reported for repair.

4. stem and disc connection is not good

Often add lubricating oil to the valve stem and stem nut to ensure the flexibility of the valve switch. Have a regular maintenance program.