Troubleshooting Method of Soft Seal Gate Valve
Classification:
Release Time:2018-03-18
The soft sealing gate valve uses compressed air as its power, and the club drives the ball to rotate 90 degrees to realize the full opening-full closing action. Its supporting the use of accessories have air filter valve, limit switch, solenoid valve. Among them, the main function of the air filter pressure reducing valve is to stabilize the pressure and filter the impurities and water vapor in the air. The valve is used for a certain period of time the frequent failure is leakage. The following is a brief introduction to the common faults of the valve and the corresponding maintenance methods. For the soft seal gate valve leakage mode, the common are the following: 1, the cylinder on the solenoid valve leakage, may be due to the pressure reducing valve in the pressure is too high. 2. The exhaust hole of the cylinder leaks
The soft sealing gate valve uses compressed air as its power, and the club drives the ball to rotate 90 degrees to realize the full opening-full closing action. Its supporting the use of accessories have air filter valve, limit switch, solenoid valve. Among them, the main function of the air filter pressure reducing valve is to stabilize the pressure and filter the impurities and water vapor in the air. The valve is used for a certain period of time the frequent failure is leakage. The following is a brief introduction to the common faults of the valve and the corresponding maintenance methods.
For the soft seal gate valve leakage mode, the common are the following:
1. The solenoid valve on the cylinder leaks, which may be due to the high air pressure in the pressure reducing valve.
2. The exhaust hole of the cylinder leaks because of the aging of the sealing ring between the two movable parts inside the cylinder and the sealing ring of the cylinder.
3. The upper and lower parts of the cylinder leak air. This is because the sealing ring between the actuator and the cylinder does not achieve the sealing effect due to the frequent activities of the actuator.
4. In addition to the above three situations, there is another situation that may cause the cylinder to leak air, that is, the spring in the cylinder is damaged, which may also cause the failure to close.
Corresponding solution:
1. Replace the sealing ring of the actuator.
2. Replace the sealing ring at the cylinder.
3, the pressure reducing valve to adjust the air pressure of 3-5kg, or the lower part of the solenoid valve to open the ventilation action several times, sometimes it is possible to replace the solenoid valve.
4. Replace the spring in the cylinder.
When solving the problem of cylinder air leakage, we must consider it according to the actual situation, such as whether the valve is open or closed. For the valve with air opening, we can first close the hand valves at both ends, then let the central control open the valve, first disassemble the connecting piece at the connection, then cut off the air source, release the air at the pressure reducing valve at this time, note that the actuator will rotate 90 ℃, and finally move the actuator back to its original position after replacement.
Related News
2026/02/28
Contact Information
+86 27-8970 8339
Address: No.5, Zhengjie, Shuangliu Street, Xinzhou District, Wuhan City, Hubei Province