How to choose the right electric actuator

Release time:

2018/03/13 21:24

1. Determine the electrical parameters according to the selected electric actuator. Due to the differences in the electrical parameters of different electric actuator manufacturers, it is generally necessary to determine the electrical parameters during design and selection, mainly including motor power, rated current, secondary control circuit voltage, etc. As a result, the mismatch between the control system and the electric actuator parameters causes faults such as trip, fuse fusing, thermal overload relay protection jump, etc. 2. Determine the output torque of the electric actuator according to the torque required by the valve. The torque required for the opening and closing of the valve determines the output torque of the electric actuator. Generally, it is determined

Operating mechanism of pneumatic check valve

Release time:

2018/03/08 21:26

1. The opening and closing direction of pneumatic valve operation shall be closed clockwise. 2, due to the pneumatic valve in the pipe network, often manual opening and closing, opening and closing the number of revolutions should not be too much, is the large diameter valve should also be within 200-600 turns. 3, in order to facilitate a person's opening and closing operation, under the condition of plumber pressure, a large opening and closing torque should be 240N-m. 4, pneumatic valve opening and closing operation end should be square tenon, and the size of standardization, and facing the ground, so that people can directly operate from the ground. The valve with wheel disc is not suitable for underground pipe network. Pneumatic check valve performance testing 1, the valve a specification of batch manufacturing, should be entrusted to the authority

General requirements for pneumatic check valves

Release time:

2018/03/05 21:26

1, the production of pneumatic valve specifications and categories, should meet the requirements of the pipeline design documents. 2. The type of pneumatic valve should indicate the requirements of the national standard number. If it is an enterprise standard, the relevant description of the model should be indicated. 3. The working pressure of the pneumatic valve is required to be ≥ the working pressure of the pipeline. On the premise of not affecting the price, the working pressure that the valve can bear should be greater than the actual working pressure of the pipeline. Any side of the pneumatic valve closed should be able to withstand 1.1 times the valve pressure value without leakage. Under the condition of valve opening, the valve body should be able to withstand twice the valve pressure. 4, pneumatic valve manufacturing standards, should explain the basis of the national standard number or enterprise standards. 5,

How to judge the quality of electric actuators

Release time:

2018/01/29 21:27

The standard system of electric actuator is mainly composed of five parts. The system structure is as follows: The first part is the basic standard, which is mainly applicable to the valve electric equipment used in various industrial fields, and is mainly based on the national standard. Including terms, signs, structural length, model preparation and other specifications. The second part is the method specification, including functional experiments, life experiments and flaw detection experiments. The third part is the product specification. Basically according to the valve electric equipment structure classification and concluded that, divided into national norms and professional norms. Including gate valve, globe valve, ball valve, plug valve, butterfly valve, diaphragm valve, trap valve, special valve electric equipment, drive equipment

Characteristics and scope of application of electric two-way valve

Release time:

2018/01/22 21:28

Features of electric two-way valve: 1. Automatic magnetic clutch control device, which can produce stable torque under the condition of pause. 2, the use of gear and screw transmission, the center of the gear around the center of the plane rolling bearing support, the valve shaft is the use of the central screw sleeve screw mosquito connection. 3. High-strength ABS flame-retardant engineering plastic shell, waterproof and knock-resistant. 4. Auxiliary manual control lever can be attached to open the valve in case of emergency. 5. With valve position indicator, the valve opening can be clearly observed at the right time. The working principle of the electric two-way valve: the driver is composed

Causes and solutions of internal leakage of pneumatic control valve

Release time:

2018/01/19 21:29

Pneumatic control valve has been more and more widely used in various industrial control systems because of its high control accuracy and convenient installation and debugging. However, in the process of use, there are also some problems, that is, the internal leakage of the valve. Common causes and solutions of internal leakage of pneumatic control valves. 1. The zero position setting of the actuator is not accurate and the valve is not fully closed. Adjustment methods: 1) close the valve manually (it must be confirmed that it has been completely closed);2) Close the valve manually with force, subject to a little effort. 3) Screw back (valve opening direction) half a turn; 4) Then adjust the limit. 2, the valve is down
< 1...646566...86 >
WeChat Public Number
Mobile phone official website
WeChat Public Number

Contact Information

+86 27-8970 8339

Tel: +86 27-8970 8619

WhatsApp: +86 181 7126 2929

E-mail: whylgd@vip.163.com

Address: No.5, Zhengjie, Shuangliu Street, Xinzhou District, Wuhan City, Hubei Province